The brocade 300 fc san switch for lenovo provides small to mediumsized enterprises with storage area network san connectivity that simplifies their it management infrastructures, improves system performance, maximizes the value of virtual server deployments, and reduces overall storage costs. Page 1 the ibm flex system fc5022 16gb san scalable switch is a gen 5 fibre channel fc highdensity, 48port switch that operates at 16 and 8 gbps fc speeds and is used in the ibm flex system chassis. Ibm flex system fc5022 product manual pdf download. It should be mentioned here that using brocade network advisor is a much preferred way of doing firmware upgrades.
The brocade 6505 and 6510 fc san switches for lenovo provide exceptional priceperformance value by delivering marketleading 16 gb gen 5 fibre channel technology and combining flexibility, simplicity, and enterpriseclass functionality that supports highly virtualized environments to meet the demands of hyperscale, private cloud storage. Ibm flex system x440 compute node initial mes seo both rp description number support csu mes e54650, 2. Description when the user attempts to update the firmware of io module ibm flex system fc5022 16gb san scalable switc h f rom the ibm flex system manager fsm, the io module goes into offline state. I decided to upgrade all our fc switches 2 brocade 6505, 2 fc5022. Ibm flex system fc5022 16 gb san scalable switch firmware update. I was in the process of setting up a new jump server a management station server virtual machine on windows server 2016 hyperv. Wan rate upgrade 2 licenses also enable the use of two 40gbe ports on a. Ibm flex system fc5022 16 gb san scalable switch firmware v7. The upgrade reloads the adapter firmware and reinitializes the link. Uxspi fails to detect the firmware version and update the. Flex system fc5022 2port 16gb fc adapter product guide. See lenovo press paper the benefits of 16 gb fibre channel in ibm flex. Lenovo flex system fc5022 16gb san scalable switch brocade firmware. View online or download ibm fc5022 user manual, product manual.
Upgrading the switch firmware upgrading the switch firmware after you locate the correct firmware to download to the ibm flex system fc5022 16gb san scalable switch, you can use either the cli or web tools to perform the download. Firmware can also be upgraded through the web interface click on switch admin and then on firmware download. Ibm brocade fcoe installation and user manual pdf download. Ibm director update manager fails to update ibm flex system. The fc5022 2port 16gb fc adapter can be used in various configurations.
Ibm system storage interoperation center ssic start your search with any of the below selection boxes. Ibm the io module ibm flex system fc5022 16gb san scalable. The fc5022 16 gbps switch delivers exceptional priceperformance for growing san workloads through a combination of marketleading 1600 mbsec throughput per port and an affordable highdensity, 12port to 48port form factor. Please view the details of your selected configuration. This adapter is based on the proven qlogic 16gb asic design and works with the 8 gb and 16 gb flex system fibre channel switches and passthru modules. Ibm flex system fc5022 2port 16gb fc adapter ibm redbooks. View and download ibm xseries 330 hardware maintenance manual online. This behavior does not allow the user to perform further operations related to that io module. Solved firmware update on ultrium hh4 ibm hardware. The fc5022 meets the demands of hyperscale, private cloud networked storage environments by delivering marketleading 168 gbps fibre channel technology as well as expert optimized, automated and inte. When upgrading windows 2008 drivers on adapters used for booting over san, install the. Ibm and brocade deliver joint solutions through a strategic relationship enabling agile and secure infrastructures for a variety of traditional and new workloads including cognitive, analytic, and. Download the latest ibm flex system fc5022 16 gb san scalable switch firmware update. Lenovos portfolio of converged systems help you to transform your data center with purposebuilt systems that incorporate servers, storage and networking into one flexible and scalable system that is managed as a single entity.
The raid functionality is provided by the external storage system. Dec 26, 2014 default user and password userid passw0rd contact me if needed. That station needed to be used to manage some aging brocade fibre channel switches. Flex system fc5172 2port 16gb fc adapter product guide.
You are not required to perform your query from the top down. Ibm flex system fc5022 16 gb san scalable switch firmware. The ibm flex system fc5022 2port 16gb fc adapter supports the following fibre channel features for enhanced performance and connectivity in the san. This adapter is based on the emulex 16 gb fibre channel asic, and it uses industryproven technology to provide highspeed, reliable access to san connected storage. Brocade 6505 and 6510 fc san switches for lenovo product. The message is also displayed if the user name or password is not valid or if the firmware path is incorrect.
Ibm flex system en4093 and en4093r 10gb ethernet scalable switch application guide for networking os 7. When the user attempts to update the firmware of io module ibm flex system fc5022 16gb san scalable switc h f rom the ibm flex system manager fsm, the io module goes into offline state. Over 500,000 inputoutput operations per second iops per port for maximum io transfer rates. Download and install the latest drivers, firmware and software. Procedures for locating firmware and documentation might vary slightly from what is described in this. I found that they are very similar and the hp firmware works on the ibm switch and vice versa. Discovering an ibm flex system fc5022 16gb san switch with the smia configuration tool. Ibm flex system enterprise chassis offers support for ibm. Once you are able to log into the cmm, you can run the command below to release it from the fsm, so you can either manage it again after the fsm has been recovered or to leave it unmanaged. Brocade 300 fc san switch for lenovo product guide withdrawn. Use the information in this section to configure the ibm flex system fc5022 16gb san switch for management by the ibm flex system manager management software. Ibm flex system fc5022 16 gb san scalable switch v8. In order to maintain a secure, wellfunctioning fibre channel fabric over the years youll need to perform a firmware upgrade now and again.
Upgrade the firmware on a brocade fibre channel switch. Machine code policies relating to system x machines will be established by lenovo and. The industryleading design of the flex system fc5022 16gb san scalable switch, flex system fc5022 24port 16gb san scalable switch, and flex system fc5022 24port 16gb esb san scalable switch provides flexible, reliable, and highperformance features that meet the demands of highly virtualized environments and cloudbased architectures. To set up an fc5022 switch for management by the ibm flex system manager management software, you must complete the procedures that are described in the following three topics setting snmp credentials for the flex system fc5022 16gb san switch. We use brocade 6505 and brocade 6547 also known as flex system fc5022 and 2 system storage from ibm san24b4 and system storage san06br which are end of life and they cant be updated to the newest version. Beginning with v5r4m5, and ptfed back to v5r4m0, there is a command called display firmware status dspfmwsts. The following figure shows the io installed in an io adapter slot 2 of the x240, which in turn is installed in the chassis. Mainframe software solutions include capabilities for ibm z mainframes to address client needs for application development and devops, infrastructure operations and management, and enterprise data protection and compliance solutions. Ibm flex system fc5022 24port 16gb esb san scalable switch, ibm flex system fc5022 16gb san scalable switch, and ibm flex system fc5022 2port 16gb fc adapter these san switch modules and hba deliver an embedded option for ibm flex system users deploying storage area networks in their enterprise. You can find a link to the ibm firmware and release notes after 6. M5014 and m5015 sas controller firmware update for windows.
Lenovo 00y3324 ibm flex system fc5022 16gb san scalable switch. After updating fsm image, firmware update for fc5022 does. All the ones with ibm fw can be installed in my ibm ts3584 after setting the sense switch pack on the base appropriately. Additional documentation, software, and firmware updates for this switch are available at fabricosv7xrelease. For detailed information on configuring these parameters, refer to the adapter configuration appendix in the brocade adapters installation. Note the firmware download for the brocade fcoe switch module is not nondisruptive. Each caution and danger statement in this document is labeled with a number. Oct 06, 2015 we dont actually apply individual ptfs to the fsp firmware as we do with ibm i. Ibm flex system manager fsm is a systems management appliance that drives efficiency and cost savings in the data center. Download the latest ibm flex system fc5022 16 gb san scalable switch firmware update ibm flex system fc5022 16 gb san scalable switch firmware v7.
With the default setting and links this will give you some headaches and. After updating fsm image, firmware update for fc5022 does not complete ibm flex system enterprise chassis 7893, 8721. Get drivers and downloads for your dell brocade 300. The fsp has a level of firmware that can be loaded from each side. New ibm xseries firmware and device driver file naming convention. Also, the firmware update of this options card fails to perform on vmware vsphere 5. The lenovo flex system fc5022 16gb san scalable switch offerings are gen 5 fibre channel fc embedded modules for lenovo flex system. Lenovo 00y3324 ibm flex system fc5022 16gb san scalable. The fc5052 2port 16 gb fibre channel adapter provides lenovo x architecture compute nodes with highspeed access to a fibre channel storage area network san. Ibm flex system fc5022 16 gb san scalable switch brocade firmware update version 7. Brocade fibre channel switches are expensive but they do deliver a very solid experience.
Oct 10, 2014 i have several lto4 full height drives taken from stk l700 library. This abstract has been concatenated due to length constraints updatexpress system pack installer uxspi fails to detect the installed firmware version of the ibm flex system fc5022 dualport 16 gigabit fibre channel fc adapter on vmware vsphere versions 5. The guest was also windows server 2016 desktop install. Select the fix group that you want to download and click continue. Lenovo flex system fc5022 16gb san scalable switches 4. Lenovo flex system fc5022 16gb san scalable switches. The ibm flex system fc5022 16gb san scalable switch is a highdensity, 48port, 16 gbps fibre channel switch that is used in the ibm flex system chassis. The flex system fc5172 2port 16gb fc adapter enables highspeed access for flex system compute nodes to connect to a fibre channel storage area network san. View and download ibm flex system fc5022 user manual online. Lenovo flex system fc5022 16gb san scalable switches product. Once brocade fabric is rebooted, reconnect using putty, log on and type the command to see the current version of firmware. As shown in the table below upgrade between one release is online more than this will require a reboot of the switch. Flex system fc5022 16gb san scalable switchupgrade 1 12ports, 88y6382.
The drives with the stk personality firmware cant be upgraded with ibm fw, either via itdt or by creating a firmware tape. The industryleading design of the flex system fc5022 16gb san scalable switch. Ibm snmpv3 notifications configuration for the ibm flex. Users can quickly and easily search through ibm s storage compatibility database to verify andor discover if an ibm storage solution is officially supported by ibm. Attention the firmware download for the switch is disruptive. This product guide provides essential presales information to. Ibm flex system fc5022 16gb san scalable switch users guide. Brocade 300 fc san switch for lenovo product guide. This will easily show you the firmware levels as well as other information. Ibm flex system manager provides a preintegrated and virtualized management environment across servers, storage, and networking that is easily managed from a single interface.
You must open a case with ibm support to receive brocade fos firmware or network advisor downloads. Configuring the ibm flex system fc5022 16gb san switch. Ports stuck as gport when configure back to default. Director update manager fails to update pharos switch ibm flex system fc5022 16gb san scalable switch if the switch has already been flashed once before. Ibm and brocade deliver joint solutions through a strategic relationship enabling agile and secure infrastructures for a variety of traditional and new workloads including cognitive, analytic, and hybrid cloud. Ibm by default uses passw0rd, but users can always suggest something else or change it at any time. Configuring storage drivers this section provides an overview of storage driver functions that you can configure for the ibm flex system fc5022 2port 16gb fc adapter on supported operating systems. Configuring the ibm flex system fc5022 16gb san switch ibm. Ibm flex system fc5022 16gb san scalable switch users. To set up an fc5022 switch for management by the ibm flex system manager management software, you must complete the procedures that are described in the following three topics. Ibm director update manager fails to update ibm flex. Be sure that no traffic is flowing through the switch during the download process. Any flex system fc5022 san scalable switch can scale nondisruptively to.
Select the download using download director and include prerequisites and corequisite fixes you can deselect the ones you dont need later options, and then click continue. So check you are happy with your multipathing setup on hosts before continuing. All code including machine code updates, samples, fixes or other software downloads provided on the fix central website is subject to the terms of the applicable license agreements. Downloading the firmware once you have found the correct firmware you want to download to the brocade fcoe switch module, you can use either the cli or web tools to do the download.
1302 583 759 1391 825 794 179 390 162 826 124 372 1495 1364 1406 157 1525 371 569 668 304 1075 942 1030 363 973 1438 1278 71 1249 1175 1094 1076 1076